Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of NORYL GTX™ Resin GTX985 - Europe - (PPE+PA*)-MF18 - Saudi Basic Industries Corporation (SABIC)

Material Data Center offers the following functions for NORYL GTX™ Resin GTX985 - Europe:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Noryl GTX datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
NORYL GTX™ 985 resin is a conductive, 18% mineral reinforced alloy of Polyphenylene Ether (PPE) + Polyamide (PA). This injection moldable grade combines high stiffness, excellent chemical resistance, and high heat resistance. NORYL GTX985 is conductive for primerless electrostatic painting and is an excellent candidate for automotive exterior trim applications.
Processing/Physical CharacteristicsValueUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 15 cm³/10min ISO 1133
Temperature 280 °C -
Load 5 kg -
ASTM Data
Melt Flow Index, MFI 16 g/10min ASTM D 1238
Temperature 280 °C -
Load 5 kg -
Mechanical propertiesValueUnitTest Standard
ISO Data
Tensile Modulus 4400 MPa ISO 527
Yield stress 65 MPa ISO 527
Yield strain 4 % ISO 527
Stress at break 60 MPa ISO 527
Strain at break 7 % ISO 527
Flexural modulus 4350 MPa ISO 178
Charpy notched impact strength, +23°C 4 kJ/m² ISO 179/1eA
Izod impact strength, +23°C 60 kJ/m² ISO 180/1U
Izod notched impact strength, +23°C, 4mm 4 kJ/m² ISO 180/1A
Izod notched impact strength, -30°C, 4mm 4 kJ/m² ISO 180/1A
ASTM Data
Tensile Strength at Yield 65 MPa ASTM D 638
Tensile Strength at Break 60 MPa ASTM D 638
Elongation at Yield 4 % ASTM D 638
Elongation at Break 7 % ASTM D 638
Flexural Modulus 4200 MPa ASTM D 790
Izod Impact notched, 1/8 in 45 J/m ASTM D 256
Izod Impact notched, Low-Temperature 40 J/m ASTM D 256
Temperature -30 °C -
Thermal propertiesValueUnitTest Standard
ISO Data
Temp. of deflection under load, 0.45 MPa 205 °C ISO 75-1/-2
Vicat softening temperature, B 195 °C ISO 306
Vicat softening temperature, 120°C/h 50N 200 °C ISO 306
Coeff. of linear therm. expansion, parallel 60 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 65 E-6/K ISO 11359-1/-2
ASTM Data
DTUL @ 66 psi 200 °C ASTM D 648
Vicat Temperature 195 °C ASTM D 1525
Other propertiesValueUnitTest Standard
Humidity absorption 1.1 % Sim. to ISO 62
Density 1250 kg/m³ ISO 1183
Density 1250 kg/m³ ASTM D 792
Processing Recommendation Injection MoldingValueUnitTest Standard
Pre-drying - Temperature 100 - 110 °C -
Pre-drying - Time 2 - 3 h -
Processing humidity ≤0.02 % -
Melt temperature 280 - 300 °C -
Mold temperature 100 - 120 °C -
Feed temperature 80 - 100 °C -
Zone 1 260 - 280 °C -
Zone 2 270 - 290 °C -
Zone 3 280 - 300 °C -
Characteristics
Processing
Injection Molding
Applications
Automotive
Regional Availability
Europe
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.